-
Kotak Serat Optik
-
Fiber Optic Splitter Box
-
Serat Optik PLC Splitter
-
Kotak Kabel Serat Bersama
-
Kabel MPO MTP
-
serat optik dikepang
-
serat optik kabel patch
-
Fiber Optic Adapter
-
Serat optik Attenuator
-
Field Installable Connector
-
FTTH tarik kabel
-
serat optik patch panel
-
Fiber Optic sambatan penutupan
-
Kit Alat Serat
-
Unit Jaringan Optik
-
Kit Pemasangan Kabel
-
Antoniokotak serat optik bagus, kualitas bagus, paket bagus, layanan bagus, tunggu pesanan baru saya. terima kasih
-
Chataikaterima kasih atas pengiriman cepat Anda setiap saat, dengan kualitas yang sama, selalu dukung saya dengan harga, terima kasih atas dukungan khusus untuk kami setiap saat. sangat menyukai perusahaan Anda, sampai jumpa lagi di China
-
Carla Louissophie sayang, suaramu sangat manis dan selalu memberi kami solusi lengkap dan balasan segera, dan membantu kami mendapatkan lebih banyak bisnis, terima kasih
-
Benjamin FernandoSaya sangat puas dengan kualitas Anda, dan Anda selalu menyelesaikan pesanan saya tepat waktu, berharap melakukan lebih banyak bisnis dengan Anda di masa mendatang, dan pasar kami meningkat, mari bekerja lebih jauh
-
Alejandro SHi teman saya, senang untuk mulai bekerja dengan Anda selama 8 tahun. dan selama ini kami membuka beberapa cabang, terima kasih untuk selalu mendukung, meskipun pasar rendah, tetapi volume penjualan kami meningkat, love you all,
0.9mm Steel Tube Fiber Optic PLC Splitter 1X16 G657A1 1.5m 0.9mm With SC UPC Connector
Hubungi saya untuk sampel dan kupon gratis.
Ada apa:0086 18588475571
Wechat wechat: 0086 18588475571
Skype: sales10@aixton.com
Jika Anda memiliki kekhawatiran, kami menyediakan bantuan online 24 jam.
xsplit ratio | 1:16 blockless splitter | connector | SC UPC |
---|---|---|---|
fiber type | corning fiber SMF -28e G657A1 | insertion loss | 13.6dB |
Uniformity (Max.) | 1.4dB | wavelength | 1260 - 1650 nm |
PDL(Max.) | 0.3dB | Standard | Telcordia GR-1221 and GR-1209 |
tube dimension | 60*12*4mm | cable diameter | 0.9mm |
cable color | input blue, output: white | ||
Cahaya Tinggi | Fiber Optic Splitter,PLC Splitter |
0.9mm Steel Tube Fiber Optic PLC Splitter 1X16 G657A1 1.5m 0.9mm With SC UPC Connector
PLC stands for Planar Lightwave Circuit. PLC splitters are used to distribute or combine optical signals. It is based on planar lightwave circuit technology and provides a low cost light distribution solution with small form factor and high reliability.
PLC Splitters provide a cost effective and space saving product suitable to the ever changing networking requirements. With it's compact size, these splitters can be utilized in in-ground and aerial pedestals as well as rack mount systems.
Installation is simple using a variety of connector types or fusion splicing.
Features:
• Singlemode PLC Splitters in a variety of package types and configurations
• Optical performance 100% factory tested
• UPC, and APC polish types available for connectorized products
• Low Insertion Loss, Back Reflection and PDL
• Telcordia GR-CORE 1221 certified
More pictures
Technical Specs for PLC Splitter with Connector
1xn SPLITTER
Item | 1x2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 | 1x128 | |
Fiber Type | G.657.A | |||||||
Working Wavelength | 1260nm~1650nm | |||||||
Standard Insertion Loss(dB) | ≤4.2 | ≤7.6 | ≤10.7 | ≤14.0 | ≤17.2 | ≤20.8 | ≤24.0 | |
P-Grade Insertion Loss(dB) | ≤4.0 | ≤7.4 | ≤10.5 | ≤13.8 | ≤17.0 | ≤20.4 | ≤23.7 | |
Uniformity(dB) | ≤0.6 | ≤0.8 | ≤0.8 | ≤1.0 | ≤1.5 | ≤2.0 | ≤2.0 | |
PDL(dB) | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.4 | ≤0.5 | |
Wavelength Dependent Loss(dB) | ≤0.6 | ≤0.8 | ≤0.8 | ≤1.0 | ≤1.5 | ≤2.0 | ≤2.0 | |
Return Loss(dB) | ≥50 | |||||||
Directivity(dB) | ≥55 | |||||||
Operating Temp.Gange | -40℃~+85℃ | |||||||
Note:The above parameter is for Splitter with connector.If w/o connector,insertion loss will reduce by 0.2dB. |
2XN splitter
Item | 2x2 | 2x4 | 2x8 | 2x16 | 2x32 | 2x64 | 2x128 | ||
Fiber Type | G.657.A | ||||||||
Working Wavelength | 1260nm~1650nm | ||||||||
Standard Insertion Loss(dB) | ≤4.4 | ≤8.0 | ≤11.0 | ≤14.6 | ≤17.8 | ≤21.0 | ≤24.4 | ||
P-Grade Insertion Loss(dB) | ≤4.2 | ≤7.7 | ≤10.8 | ≤14.1 | ≤17.4 | ≤20.7 | ≤24.0 | ||
Uniformity(dB) | ≤0.8 | ≤1.0 | ≤1.2 | ≤1.5 | ≤1.8 | ≤2.0 | ≤3.0 | ||
PDL(dB) | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.4 | ≤0.5 | ||
Wavelength Dependent Loss(dB) | ≤0.8 | ≤1.0 | ≤1.2 | ≤1.5 | ≤1.8 | ≤2.0 | ≤3.0 | ||
Return Loss(dB) | ≥50 | ||||||||
Directivity(dB) | ≥55 | ||||||||
Operating Temp.Gange | -40℃~+85℃ | ||||||||
Note:The above parameter is for Splitter with connector.If w/o connector,insertion loss will reduce by 0.2dB. |
PLC PRODUCTION LINES: